2,869 research outputs found

    Reanalysis of the GALLEX solar neutrino flux and source experiments

    Full text link
    After the completion of the gallium solar neutrino experiments at the Laboratori Nazionali del Gran Sasso (GALLEX}: 1991-1997; GNO: 1998-2003) we have retrospectively updated the GALLEX results with the help of new technical data that were impossible to acquire for principle reasons before the completion of the low rate measurement phase (that is, before the end of the GNO solar runs). Subsequent high rate experiments have allowed the calibration of absolute internal counter efficiencies and of an advanced pulse shape analysis for counter background discrimination. The updated overall result for GALLEX (only) is (73.4 +7.1 -7.3) SNU. This is 5.3% below the old value of (77.5 + 7.5 -7.8) SNU (PLB 447 (1999) 127-133) with a substantially reduced error. A similar reduction is obtained from the reanalysis of the 51Cr neutrino source experiments of 1994/1995.Comment: Accepted by Physics Letters B January 13, 201

    Re-Examination of Possible Bimodality of GALLEX Solar Neutrino Data

    Full text link
    The histogram formed from published capture-rate measurements for the GALLEX solar neutrino experiment is bimodal, showing two distinct peaks. On the other hand, the histogram formed from published measurements derived from the similar GNO experiment is unimodal, showing only one peak. However, the two experiments differ in run durations: GALLEX runs are either three weeks or four weeks (approximately) in duration, whereas GNO runs are all about four weeks in duration. When we form 3-week and 4-week subsets of the GALLEX data, we find that the relevant histograms are unimodal. The upper peak arises mainly from the 3-week runs, and the lower peak from the 4-week runs. The 4-week subset of the GALLEX dataset is found to be similar to the GNO dataset. A recent re-analysis of GALLEX data leads to a unimodal histogram.Comment: 14 pages, 8 figure

    Sampling Theorie und Interpolierende Skalierungsfunktionen in höheren Dimensionen

    Get PDF

    Results of ultra-low level 71ge counting for application in the Gallex-solar neutrino experiment at the Gran Sasso Underground Physics Laboratory

    Get PDF
    It has been experimentally verified that the Ultra-Low-Level Counting System for the Gallex solar neutrino experiment is capable of measuring the expected solar up silon-flux to plus or minus 12% during two years of operation

    Highly Sensitive Gamma-Spectrometers of GERDA for Material Screening: Part 2

    Full text link
    The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done using low-level gamma-spectroscopy. In order to provide sufficient selective power in the mBq/kg range and below, the employed gamma-spectrometers themselves have to meet strict material requirements, and make use of an elaborate shielding system. This article gives an account of the setup of two such spectrometers. Corrado is located in a depth of 15 m w.e. at the MPI-K in Heidelberg (Germany), GeMPI III is situated at the Gran-Sasso underground laboratory at 3500 m w.e. (Italy). The latter one aims at detecting sample activities of the order ~0.01 mBq/kg, which is the current state-of-the-art level. The applied techniques to meet the respective needs are discussed and demonstrated by experimental results.Comment: Featured in: Proceedings of the XIV International Baksan School "Particles and Cosmology" Baksan Valley, Kabardino-Balkaria, Russia, April 16-21,2007. INR RAS, Moscow 2008. ISBN 978-5-94274-055-9, pp. 233-238; (6 pages, 4 figures

    Symplectic Symmetry of the Neutrino Mass and the See-Saw Mechanism

    Get PDF
    We investigate the algebraic structure of the most general neutrino mass Hamiltonian and place the see-saw mechanism in an algebraic framework. We show that this Hamiltonian can be written in terms of the generators of an Sp(4) algebra. The Pauli-Gursey transformation is an SU(2) rotation which is embedded in this Sp(4) group. This SU(2) also generates the see-saw mechanism.Comment: 11 pages, REVTE

    Cleaning the USNO-B Catalog through automatic detection of optical artifacts

    Full text link
    The USNO-B Catalog contains spurious entries that are caused by diffraction spikes and circular reflection halos around bright stars in the original imaging data. These spurious entries appear in the Catalog as if they were real stars; they are confusing for some scientific tasks. The spurious entries can be identified by simple computer vision techniques because they produce repeatable patterns on the sky. Some techniques employed here are variants of the Hough transform, one of which is sensitive to (two-dimensional) overdensities of faint stars in thin right-angle cross patterns centered on bright (<13 \mag) stars, and one of which is sensitive to thin annular overdensities centered on very bright (<7 \mag) stars. After enforcing conservative statistical requirements on spurious-entry identifications, we find that of the 1,042,618,261 entries in the USNO-B Catalog, 24,148,382 of them (2.3 \percent) are identified as spurious by diffraction-spike criteria and 196,133 (0.02 \percent) are identified as spurious by reflection-halo criteria. The spurious entries are often detected in more than 2 bands and are not overwhelmingly outliers in any photometric properties; they therefore cannot be rejected easily on other grounds, i.e., without the use of computer vision techniques. We demonstrate our method, and return to the community in electronic form a table of spurious entries in the Catalog.Comment: published in A

    Sonnenneutrinos: zurück zur Astrophysik

    Get PDF
    Nachdem der teilchenphysikalische Aspekt in den letzten Jahren dominierte, konzentriert sich die Sonnenneutrino-Forschung nun wieder auf ihren ursprünglichen Gegenstand, die Sonnenphysik. Eine Analyse aller Sonnenneutrino-Daten erlaubt den Schluss, dass der Anteil des CNO-Zyklus an der Energieerzeugung in der Sonne kleiner als 7,3% ist

    V2:Performance of the solid deuterium ultra-cold neutron source at the pulsed reactor TRIGA Mainz

    Full text link
    The performance of the solid deuterium ultra-cold neutron source at the pulsed reactor TRIGA Mainz with a maximum peak energy of 10 MJ is described. The solid deuterium converter with a volume of V=160 cm3 (8 mol), which is exposed to a thermal neutron fluence of 4.5x10^13 n/cm2, delivers up to 550 000 UCN per pulse outside of the biological shield at the experimental area. UCN densities of ~ 10/cm3 are obtained in stainless steel bottles of V ~ 10 L resulting in a storage efficiency of ~20%. The measured UCN yields compare well with the predictions from a Monte Carlo simulation developed to model the source and to optimize its performance for the upcoming upgrade of the TRIGA Mainz into a user facility for UCN physics.Comment: 23 pages, 8 figure

    Air temperature and inflammatory and coagulation responses in men with coronary or pulmonary disease during the winter season

    Get PDF
    Background and Objective Air temperature changes are associated with increased cardiovascular and respiratory risk, but the roles of inflammatory and coagulation markers are not well understood. We investigated the associations between temperature and several blood markers in patients with coronary heart disease (CHD) and pulmonary disease (PD). Methods Two studies were conducted in Erfurt, Germany, over two successive winters. 578 and 381 repeated blood measurements were collected from 57 CHD and 38 PD patients, respectively. Data on patient characteristics and disease history were gathered at baseline. Meteorological data were collected from existing networks. Associations were analysed using additive mixed models with random patient effects. Effect modification by diabetes status was investigated only in CHD patients, as only two PD patients had diabetes. Results Mean daily air temperature varied between -13 degrees C and 16 degrees C in both study periods. A 10 degrees C decrease in the 5-day temperature average before blood withdrawal led to an increase in platelet counts (% change from the mean: 3.0%, 95% CI 0.6% to 5.5%) and fibrinogen (5.5%, 1.3% to 9.7%), no change in C-reactive protein in PD patients, and a decrease in C-reactive protein in CHD patients. A 2-day delayed increase in factor VII associated with temperature decrease was seen in CHD patients (4.9%; 0.7% to 9.2%), while PD patients showed no effect. `Effects in CHD patients without diabetes' into `Effects on factor VII in CHD patients without diabetes'. Conclusions This study suggests that temperature decrease is associated with change in several blood parameters. The complex interplay of blood markers at low temperature may contribute to the observed association between cold and cardiovascular mortality and morbidity
    • …
    corecore